MAKECONV(1) ICU 72.1 Manual MAKECONV(1)

NAME


makeconv - compile a converter table

SYNOPSIS


makeconv [ -h, -?, --help ] [ -c, --copyright ] [ -v, --verbose ] [
-d, --destdir destination ] convertertable ...

DESCRIPTION


makeconv converts the ICU converter table convertertable into a
binary file. The binary file has the same base name as convertertable
but has a .cnv extension (instead of the typical .ucm extension of
the convertertable file). This binary file can then be read directly
by ICU, or used by pkgdata(1) for incorporation into a larger archive
or library.

The convertertable must be in the ICU ucm (Unicode Codepage Mapping)
format in order to be understood by makeconv. The ICU ucm format is
similar to the IBM NLTC upmap/tpmap/rpmap files. Comments in the
convertertable are handled as follows. If a comment (starting with a
`#' sign) that is after some text does contain the fallback indicator
`|' then only the text starting with the `#' sign, and ending before
the `|' sign, is ignored. Otherwise, or if the comment is the first
thing on the line, the comment runs up to the end of the line. This
special handling of comments is to accommodate the practice of
putting fallback information in comments in the strict IBM NLTC ucmap
format.

Note that new converters will be automatically found by ICU after
their installation in ICU's data directory. They do not need to be
listed in the convrtrs.txt(5) converters aliases file in order to be
available to applications using ICU. They do need to be listed there
if one wants to give them aliases, or tags, though.

OPTIONS


-h, -?, --help
Print help about usage and exit.

-c, --copyright
Include a copyright notice in the binary data.

-v, --verbose
Display extra informative messages during execution.

-d, --destdir destination
Set the destination directory to destination. The default
destination directory is specified by the environment variable
ICU_DATA.

CAVEATS


If an existing converter table is changed and recompiled using
makeconv, the resulting binary file must be packaged in the same way
that it was packaged initially. For example, if converters were
grouped together in an archive or a library with pkgdata(1), then the
archive or library must be rebuilt with the new binary file. A
standalone binary converter file will not take precedence over a
packaged one.

ENVIRONMENT


ICU_DATA Specifies the directory containing ICU data. Defaults to
${prefix}/share/icu/72.1/. Some tools in ICU depend on the
presence of the trailing slash. It is thus important to
make sure that it is present if ICU_DATA is set.

VERSION


72.1

COPYRIGHT


Copyright (C) 2000 IBM, Inc. and others.

SEE ALSO


convrtrs.txt(5)
pkgdata(1)


ICU MANPAGE 16 April 2002 MAKECONV(1)